Blog · Property management
DG Backup Charges in Apartments: How Bengaluru Societies Bill
How DG backup is charged in Bengaluru apartments: fixed charges per kVA, metered DG units, what drives the cost, safety rules and how to check your bill.
By the Homes in Bangalore editorial teamLast reviewed 5 min read1,188 words

Short answer
DG backup is power supplied by an apartment complex's diesel generator sets when grid supply from BESCOM fails. Bengaluru associations commonly bill it in two parts: a fixed monthly charge based on the backup load allotted to your flat in kVA, and a variable charge for the units your flat draws from the generator, recorded by a DG meter or a dual-source meter. Some smaller buildings simply include it in monthly maintenance.
Key takeaways
- ◆DG backup in apartments is usually billed as a fixed monthly charge linked to your allotted backup load in kVA, plus a metered charge for units used during power cuts.
- ◆The metered rate should be traceable to the association's diesel bills and the units its generators actually produced.
- ◆A promise of '100% power backup' can mean very different things, so ask which loads are covered and how many kVA each flat gets.
- ◆Generators must meet emission, noise and fire-safety requirements, which adds to the running cost the association passes on (verify current norms).
What DG backup covers in an apartment
Every complex with generators backs up its essential common loads: lifts, water pumps, common lighting, the sewage treatment plant, fire systems and security. Flat backup is where projects differ. Some offer backup for the whole flat, some a fixed load of a few kVA per flat, and some cover only common areas.
Marketing terms like '100% power backup' don't tell you much on their own. Before you buy or rent, ask these questions.
- Is backup provided to flats, or only to common areas?
- How many kVA of backup is allotted to your flat, and is it written in the agreement?
- Which appliances can run on backup: air conditioners, geysers, induction cooktops?
- Is there a load limiter that cuts supply if you exceed your allotment?
- How quickly does the changeover from grid to generator happen?
How DG backup charges are usually billed
Associations use one method or a combination of them. Fixed charges recover costs that don't depend on outages, while metered charges recover the fuel actually used.
| Method | How it works | Points to note |
|---|---|---|
| Fixed charge per kVA | A monthly amount for each kVA of backup allotted to the flat | Covers costs such as maintenance contracts and depreciation; payable even in months with few outages |
| Metered DG units | A DG meter or dual-source meter records units drawn during outages, billed at a per-unit rate | Fair to light users; the rate must be revised as diesel costs change |
| Included in maintenance | Backup costs are built into the monthly maintenance charge | Simple to run, but light users subsidise heavy users |
| Prepaid dual-source meter | One meter records grid and DG units separately and deducts DG usage from a prepaid balance (verify how grid units are billed in your building) | Real-time tracking; depends on transparent rates and a reliable vendor |
What drives the cost of DG power
Generator power usually costs more per unit than grid power, and the per-unit cost depends mainly on the price of diesel and how many units each litre produces. Efficiency drops when a large set runs at a light load, which is why oversized generators can push costs up. Maintenance contracts, lubricants, filters, operator wages and eventual overhauls add to the total.
The example uses made-up figures, not market rates, to show how a bill is built. If a month's diesel cost ₹50,000 and the generators logged 2,000 units, fuel alone works out to ₹25 per unit (₹50,000 divided by 2,000). A real per-unit rate may add maintenance and operator costs to fuel, but the association should be able to show how it got there.
| Item | Working | Amount |
|---|---|---|
| Fixed charge | 3 kVA allotted × ₹100 per kVA | ₹300 |
| Metered DG units | 40 units × ₹25 per unit | ₹1,000 |
| Total for the month | ₹300 + ₹1,000 | ₹1,300 |
Emission, noise and fire-safety rules
Diesel generators must meet emission and noise standards set by the Central Pollution Control Board and enforced in the state by the Karnataka State Pollution Control Board, which typically means acoustic enclosures and a properly designed exhaust stack (verify current norms and any consent requirements). Newer emission standards have pushed some buildings towards upgraded or retrofitted sets (verify).
Diesel stored near basements and parking is a fire risk, and storage quantities and arrangements are subject to fire-safety rules (verify with the Karnataka State Fire and Emergency Services). Associations that add rooftop solar or battery storage for common loads can reduce generator run hours, though each option needs its own approvals and maintenance.
How to check whether your DG charges are fair
If DG charges feel high, ask for evidence rather than arguing over the rate. A well-run association should be able to produce these records without fuss.
Generator overhauls and replacements are classic sinking fund items, so check that the reserve is planned for them rather than left to a special levy. Our post on sinking funds explains how to plan for big replacements.
- Monthly diesel purchase bills and fuel stock registers
- Generator run-hour logs and total units generated each month
- The calculation behind the per-unit rate, compared with fuel cost per unit from the logs
- When the fixed per-kVA charge was last revised, and what it covers
- Calibration records for DG meters, and meter readings shown on each bill
- The scope of the generator maintenance contract, and whether major overhauls come from the sinking fund
Frequently asked questions
How is DG backup charged in apartments?+
Most Bengaluru apartment associations charge DG backup in two parts: a fixed monthly charge based on the backup load allotted to each flat in kVA, and a metered charge per unit drawn from the generator during power cuts. Some buildings include backup in monthly maintenance instead, and some use prepaid dual-source meters. The per-unit rate should reflect diesel cost and generator efficiency, plus any maintenance cost the association adds.
Do I pay DG backup charges if there are no power cuts?+
Usually you still pay the fixed part. The fixed charge per kVA covers costs that don't depend on outages, such as the generator's maintenance contract, periodic servicing and depreciation. The metered part depends on units actually drawn, so it falls in months with few outages. If your building bundles backup into maintenance, you pay the same amount however often the generator runs.
Can I increase the DG backup load for my flat?+
Sometimes. Whether the association can allot extra kVA depends on the spare capacity of its generators, the changeover arrangements and the bye-laws. If spare capacity exists, the association may raise your fixed charge in proportion to the extra load. Ask in writing, and expect a technical check by the facility manager or an electrical contractor before any change is made.
Who pays DG charges in a rented flat, the owner or the tenant?+
DG unit charges reflect actual usage, so rental agreements in Bengaluru usually make the tenant pay them, along with grid electricity. The fixed per-kVA charge is often treated as part of maintenance, so whoever pays maintenance under the agreement usually pays it too. Write the split clearly into the rental agreement and check the final DG bill when the tenant moves out.
Sources
Useful next steps
Property management services for this